Hot Water Heating Systems: Modern Conventional Boiler / Conventional Systems

In a hot water (hydronic) heating systems,becomes trapped in the convectors, preventing
water is heated in a gas, oil, or electrichot water from entering. To release this air,
boiler and circulated through pipes tomost convectors are installed with air vents,
convectors; older systems use radiators. Whenwhich can be opened with a screwdriver until
the thermostat calls for heat, a "circulatorhot water squirts out.Efficiency can be
pump" in the boiler return line moves waterimproved by insulating pipes, or by partially
through the pipes to the convectors, whichclosing convector shut-off valves in rooms
give up heat to the rooms. When therequiring less heat. Systems can be divided
circulator is not pumping, a "flow-controlinto zones with one or more rooms controlled
valve" stops the water flow to protect theby a thermostatic "zone valve".
convectors from overheating.Older gravityAlternatively, a separate circulator is
systems have no circulator pumps and dependsometimes used for each zone, or you could
on lighter, heated water rising in the pipeshave thermostatic valves installed on each
to the radiators; and cooler, heavier waterconvector, but these options might be
gravitating back to the boiler.Single-pipeexpensive.Boilers are more expensive to
systems, with short branch lines to eachinstall than other systems, but are generally
convector, are used in small to medium-sizedtrouble-free, very efficient, and last much
houses. Two pipe systems use separate supplylonger than other types of heating systems.*
and return pipes, and are more appropriateSome newer systems use non-metallic
for larger houses, because cool return waterpiping, installed in/under floors, to
from convectors doesn't pass through others.distribute hot water in the rooms to be
This maintains a higher water temperature atheated. In some cases, a domestic oil or
far ends of the system.As heated watergas-fired hot water tank can be fitted with a
expands, an air-tight "expansion tank" on thecirculating pump, and the hot water directed
hot side of the boiler takes in the excess;to convectors or a heating coil installed in
and if the tank fills up, a "safety-reliefa hot air plenum.Copyright Gil Strachan - All
valve" on top of the boiler relieves therights reserved.Gil Strachan is a
pressure. If this valve leaks under normalprofessional home inspector, representing
operating pressure, you can open it (bewareElectrospec Home Inspection Services in
of hot spray) and close it. If the drippingeast-central Ontario, Canada since 1994.
continues, the relief valve needs to beVisit to learn more about home
replaced.Twice a year, if the circulator pumpinspections."The  Home  Reference  Book"
and motor are not permanently lubricated, add
a couple drops of oil. If you want to work onYou can probably find a home inspection for
your boiler, shut off the power, let it coola little less than what we ask, but you
down and then drain the system if necessary.probably won't find the Home Reference Book.
Older tanks can be drained when they're tooA $60 value, this solutions-oriented
full, but newer "diaphragm tanks" should bereference tool comes free with every
drained only by qualified serviceinspection we perform.It's the first tool you
personnel.When first heating cold water in ashould have around the house!