Hot Water Heating Systems: Modern Conventional Boiler / Conventional Systems

In a hot water (hydronic) heatingin a hydronic system, it releases air
systems, water is heated in a gas, oil,which becomes trapped in the convectors,
or electric boiler and circulatedpreventing hot water from entering. To
through pipes to convectors; olderrelease this air, most convectors are
systems use radiators. When theinstalled with air vents, which can be
thermostat calls for heat, a "circulatoropened with a screwdriver until hot
pump" in the boiler return line moveswater squirts out.Efficiency can be
water through the pipes to theimproved by insulating pipes, or by
convectors, which give up heat to thepartially closing convector shut-off
rooms. When the circulator is notvalves in rooms requiring less heat.
pumping, a "flow-control valve" stopsSystems can be divided into zones with
the water flow to protect the convectorsone or more rooms controlled by a
from overheating.Older gravity systemsthermostatic "zone valve".
have no circulator pumps and depend onAlternatively, a separate circulator is
lighter, heated water rising in thesometimes used for each zone, or you
pipes to the radiators; and cooler,could have thermostatic valves installed
heavier water gravitating back to theon each convector, but these options
boiler.Single-pipe systems, with shortmight be expensive.Boilers are more
branch lines to each convector, are usedexpensive to install than other systems,
in small to medium-sized houses. Twobut are generally trouble-free, very
pipe systems use separate supply andefficient, and last much longer than
return pipes, and are more appropriateother types of heating systems.*
for larger houses, because cool returnSome newer systems use non-metallic
water from convectors doesn't passpiping, installed in/under floors, to
through others. This maintains a higherdistribute hot water in the rooms to be
water temperature at far ends of theheated. In some cases, a domestic oil
system.As heated water expands, anor gas-fired hot water tank can be
air-tight "expansion tank" on the hotfitted with a circulating pump, and the
side of the boiler takes in the excess;hot water directed to convectors or a
and if the tank fills up, aheating coil installed in a hot air
"safety-relief valve" on top of theplenum.Copyright Gil Strachan - All
boiler relieves the pressure. If thisrights reserved.Gil Strachan is a
valve leaks under normal operatingprofessional home inspector,
pressure, you can open it (beware of hotrepresenting Electrospec Home Inspection
spray) and close it. If the drippingServices in east-central Ontario, Canada
continues, the relief valve needs to besince 1994. Visit to learn more about
replaced.Twice a year, if the circulatorhome inspections."The Home Reference
pump and motor are not permanentlyBook"
lubricated, add a couple drops of oil.You can probably find a home inspection
If you want to work on your boiler, shutfor a little less than what we ask, but
off the power, let it cool down and thenyou probably won't find the Home
drain the system if necessary. OlderReference Book. A $60 value, this
tanks can be drained when they're toosolutions-oriented reference tool comes
full, but newer "diaphragm tanks" shouldfree with every inspection we
be drained only by qualified serviceperform.It's the first tool you should
personnel.When first heating cold waterhave around the house!