How to Operate a Genverter Power System

Operating a genverter based power is not difficult,lost. The most expensive part of charging it
and really isn't technical. In our home, our kidsgetting the batteries over that last 10% of
knew how to read the meter, and start thecharge. Many times we stop before then, but not
generator since they were about 11 years old.always as explained below.maintenance operation
The real key to operating the system correctly, isDeep cycle batteries have a wear out mechanism
to have and understand the metering betweenthat occurs when they stay below 75% charge
the batteries and the charging system.silent modefor any length of time. It is called sulfating, and is
When the system starts off with fully chargedcovered in detail elsewhere on Its ironic, that
batteries, you have power in what I call "silentbatteries last the longest if you never discharge
mode". You can have lights and other creaturethem, that is, use them! This third mode of
comforts without using any gas, since the invertergenverter operation is used to keep the batteries
is converting the stored battery power intohealthy and to extend their life.
normal home AC. You may have certain largeDuring normal operation, we like to do what is
loads that may not be appropriate during this timecalled an equalize charge for our lead acid
because they would drain the stored energybatteries. It is a small investment that will help the
quickly. In our home these are items like thebattery bank last extra years. The charging
dishwasher, the well pump, and Jackie's favoritesystem is run and the voltage is permitted to go
electric iron.to a higher than normal voltage for a few hours.
Having a device or meter that measures powerFor example on a 12V battery bank, we let it go
flowing into or out of the battery bank is veryup to 14.5V and watch the electrolyte in the
important. With the meter counting thebatteries bubble some. This helps break up the
Amp-Hours or "juice" flowing out of the batterysulfation that occurs during normal operation. This
bank, it is easy to see when we've used 30-40%operation does take extra fuel, but is a good long
of the total capacity. When this level is reached,term investment
its time to make sure we start charging in aSometimes it is possible if we leave a few days in
serious way by starting up our generator chargingthe summer, to let our solar charging and solar
source.free power modecontroller to automatically do the equalize charge
After charging a short while, it becomes freefor us! Basic genverter operation can be broken
power time, since the generator is not fully loadedup into 3 modes; silent mode, free power mode,
with the task of battery charging. This is the timeand maintenance mode. Your power consumption
to run those big loads mentioned above. We call itat any time should match the genveter mode.
free, because for the most part, this extraHaving and monitoring your charging meter will
power not used in charging will be lost! Ashelp determine how your system should be
batteries get some charge, they accept lessoperated at any given time.
current and more generator power potential is